Click to enlarge image
|
Model Number |
80RND,100RND, 120RND, 140RND |
Applications
- Medical, Dental & E.N.T. equipment
- As an oil-less air compressor and Vacuum pump
- Oxygen Concentrator & Ozone generator
- Semi Conductor processing , Chip mounter
- Packing machine, Food processing
- Environmental equipment
- Industrial equipment
Technical Specifications
|
Oil-less Piston Pump , Double Head Type (Parallel Connecting) |
|
Model |
140RND |
120RND |
100RND |
80RND |
|
Head Config |
Pressure / Vacuum |
|
Free Flow |
140 LPM |
120 LPM |
100 LPM |
80 LPM |
|
Max. Vacuum |
700 mmHg |
690 mmHg |
680 mmHg |
650 mmHg |
|
Max. Pressure |
2 bar |
4 bar |
7 bar |
7 bar |
|
Connecting Type |
PT 1/4 " |
|
Dimensions |
240(L) x 157(H) x 118(W) mm |
|
Installation Hole |
202 X 84 mm / M6 Tap |
|
Weight |
7.1 Kg |
|
Noise Level |
55~57 dB |
|
Motor Power |
200 W |
|
Motor Type |
Capacitor start, Equipped with cooling fan & Thermal Protector |
|
Power source |
100~110VAC(50/60Hz), 200~220VAC(50/60Hz), 230~240VAC(50Hz) |
Above data are based on 220VAC/60Hz, please contact us for future information.
Performance Curves
Above data are based on 220VAC/60Hz, please contact us for future information. Enlarge Performance curve
Rawing
|
|
|
|
| |
|
|
|